AC 300 – Three-cylinder compressor, with air drier
Information intended for dental healthcare professionals.
Technical data (Cattani)
| Rated voltage | 230 V — (230V 50Hz 1~) |
| Supply voltage with drier | AC 300 - 3 cylinder compressor with air dryer (230V / 50Hz 1˜) (400V / 50Hz 3˜) (220V / 60Hz 1˜) |
| Rated frequency | 50 Hz — (230V 50Hz 1~) |
| Supply phases | 1 |
| Rated power 220v 60hz single phase | 1,75 kW |
| Rated power 230v 50hz single phase | 1,5 kW |
| Rated power 240v 50hz single phase | 1,5 kW |
| Rated power 400v 50hz three phase | 1,5 kW |
| Rated current 220v 60hz single phase | 12,2 A |
| Rated current 230v 50hz single phase | 10,2 A |
| Rated current 240v 50hz single phase | 9,2 A |
| Rated current 400v 50hz three phase | 3,7 A |
| Air output at 5 bar | 238 N l/min |
| Air output per cylinder | Each cylinder of the compressor produces approximately 60 l/min air at about 5 bar pressure |
| Air tank | 45 l |
| Dried air enters tank | L'air, ainsi desséché et filtré hygiéniquement, entre dans le réservoir (M) pour être utilisé — L’air, ainsi desséché et filtré hygiéniquement, entre dans le réservoir (M) pour être utilisé. |
| Tank internal coating | The inside of the tank is painted with a resin approved for food contact and having antibacterial properties, to ensure good preservation of the air |
| Sound pressure level with canalized air | 73.6 dB(A) — Sound pressure level: 73.6 dB (A). |
| Sound pressure level in sound cabinet | 52 dB(A) — Sound-Reducing Cabinet: W840 D700 H887 (mm) Noise Level: 52dB(A) |
| Sound pressure level measurement | Sound pressure level detected according to ISO 3746-1979 (E); parameters: d = 1.5, background noise <38 dB(A), instrument Bruel & Kjaer type 2232 — Sound pressure level detected according to ISO 3746-1979 (E). Parameters: d = 1.5 - background noise <38 dB(A) - instrument Bruel & Kjaer type 2232. |
| Sound pressure level measurement distance | 1,5 m |
| Sound pressure level | 68 dB(A) — Sound pressure level: 68 dB (A). |
| Width | 620 mm |
| Width with cover and drier | 720 mm |
| Width with cover without drier | 720 mm |
| Width with drier | 620 mm |
| Width without drier | 620 mm |
| Depth | 520 mm |
| Depth with cover and drier | 600 mm |
| Depth with cover without drier | 580 mm |
Indications and sizing
- Sizing instrument consumption : It is capable of supplying an instrument with about 50/60 l/min* consumption at 2/3 bar pressure. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 11)
- Sizing model selection basis : The selection of the oil free compressor model is made in reference to the compressed air requirements. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 11)
- Suggested number of surgeries : AC300 3 cylinder - up to 4 surgeries (running simultaneously) (Source : Oil-Less Compressors Brochure (Cattani ESAM UK), p. 3)
Installation
- Installation air conditioning : Air conditioning may be an option dependent on the size and position of the plant area. (Source : Oil-Less Compressors Brochure (Cattani ESAM UK), p. 4)
- Installation airline routing : It is most important that the airline is designed and routed correctly to ensure the airflow is distributed evenly to all surgeries. (Source : Oil-Less Compressors Brochure (Cattani ESAM UK), p. 4)
- Installation clean pipework before start : Before starting the machines make sure that the distribution pipe work is clean internally as heavy debris can damage the equipment. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 12)
- Installation closed loop piping : A closed loop system keeps the pressure constant as configured for use. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 11)
- Installation commissioning tests : After the installation, the technician shall perform the regulatory and functional tests and check direction of motor rotation. Mains voltage and electrical absorption shall also be tested. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 12)
- Installation dispose of packaging : Éliminer le carton d’emballage dans le respect des normes en vigueur. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 9)
- Installation earth connection : Earth connections are mandatory for both single and three phase machines. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 12)
- Installation floor drain : Installation of a floor waste connected to the sewer for any possible liquid spillage is recommended. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 12)
- Installation handling equipment : À l’exception des modèles les plus petits, tous les autres compresseurs doivent être déplacés avec des équipements adaptés. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 15)
- Installation handling handles : The compressor is equipped with handles for safe handling. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 15)
- Installation lift by handles only : En tout état de cause, pour un transport en toute sécurité (à la main ou par gerbeur) ne soulever le compresseur qu’à l’aide des poignées. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 15)
- Installation no extension cords : Do not use extension cords or multiple sockets to connect power to the appliance. Plug the appliance power cord directly into the power outlet socket. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 9)
User maintenance
- Consumable hepa h14 filter cartridges : HEPA H14 replacement filter cartridges are provided with fitting and maintenance instructions. (Source : COMPRESSEUR SANS HUILE À 1-2-3 CYLINDRES, p. 14)
- Consumable intake filter hepa h14 : Antibacterial filter Hepa H14 item 168429 (10) (Source : Manutenzione straordinaria aspiratori e compressori, p. 2)
- Maintenance 12 months bearings : Check (preferably by means of a vibrometer) the good conditions of the bearings (12)***. (Source : Manutenzione straordinaria aspiratori e compressori, p. 2)
- Maintenance 12 months charging time : Verify the charging time (from 6 to 8 bar = 45-50 sec.) (Source : Manutenzione straordinaria aspiratori e compressori, p. 2)
- Maintenance 12 months drying column : Check the functioning of the drying column and of the moisture drainage electrovalve (8) (Source : Manutenzione straordinaria aspiratori e compressori, p. 2)
- Maintenance 12 months head filters : In clean air environments*, clean with compressed air the head filters** - replace them every 12 months (10) (Source : Manutenzione straordinaria aspiratori e compressori, p. 2)
- Maintenance 12 months intercooler fans : Check the functioning of intercooler fans (9) (Source : Manutenzione straordinaria aspiratori e compressori, p. 2)
- Maintenance 12 months tank drain check : Open the drain screw at the bottom of the reservoir tank. Ensure that only dry air is being expelled, than close the drain screw (11) (Source : Manutenzione straordinaria aspiratori e compressori, p. 2)
- Maintenance bearing replacement : It is necessary to use specific tools to replace the bearings, this is why we recommend to send the heads back to Cattani. (Source : Manutenzione straordinaria aspiratori e compressori, p. 2)
- Maintenance check capacitor : Check the capacitor capacity (-5% max) (Source : Manutenzione straordinaria aspiratori e compressori, p. 2)
- Maintenance check fans : Check the functioning of ventilators (5) (Source : Manutenzione ordinaria aspiratori e compressori, p. 2)
- Maintenance check room temperature : Check temperature in the plant room (it must be between + 5 °C and + 35 °C) (Source : Manutenzione ordinaria aspiratori e compressori, p. 2)
Accessories (sold separately)
- Accessory sound cabinet weather exposure : It can be exposed to direct sun heat, rain and frost.