Skip to Content

Micro-Smart without box

https://www.axemed.be/web/image/product.template/12511/image_1920?unique=68b7d0e

Information intended for dental healthcare professionals.

Technical data (Cattani)

Rated voltage230 V
Supply phases1
Maximum flow900 l/min
Default vacuum level setpoint step 1 minimum level70 mbar
Default vacuum level setpoint step 2 medium level100 mbar
Default vacuum level setpoint step 3 maximum level210 mbar
Sound pressure level with canalized air64-71 dB(A) — 210mbar (continuous service) 64-71dB(A)
Sound pressure level measurement methodSound pressure level detected according to ISO 3746-1979 (E). Parameters: r = 1.5, background noise 34 dB(A), Bruel & Kjaer type 2232 instrument. — Sound pressure level detected according to ISO 3746-1979 (E). Parameters: r= 1.5 - background noise: 34 dB(A) - Bruel & Kjaer type 2232 instrument.
Sound pressure with box for indoorsSound pressure with box for indoors 41 dB(A) 48 dB(A)
Sound pressure level with box for outdoorsSound pressure with box for outdoors 54,5 dB(A) 61,2 dB(A)
Sound pressure level with plastic boxSound pressure with plastic box 63 dB(A) 68,5 dB(A)
Sound pressure level with sound reducing cabinet41 - 48 dB(A)
Sound pressure level with sound reducing cover63 - 68.5 dB(A)
Sound pressure model without boxSound pressure without box 64 dB(A) 71 dB(A)
Width370 mm
Depth340 mm
Dimensions H590 mm
Protection against humidityCommon
Transport storage max humidityPackages cannot be exposed to water and spraying and cannot withstand humidity above 70%. %
Default blower current limit3,9 A
Blower target frequency60 Hz
Default blower target frequency step 2 medium level85 Hz
Default blower target frequency step 3 maximum level120 Hz
Default centrifuge separator current limit3,2 A
Default centrifuge separator frequency75 Hz
Diagnostic test inlet closed centrifuge separator current0,8 - 1,2 A
Diagnostic test inlet closed frequency reached85 Hz
Diagnostic test inlet closed head reached190 - 210 mbar
Diagnostic test inlet closed total current3,2 - 4 A
Diagnostic test inlet open centrifuge separator current0,8 - 1,2 A

Installation

  • Installation carton recycling : Le carton étant recyclable nous vous recommandons de l’éliminer selon les normes en vigueur. (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 12)
  • Installation dental unit contacts : Make sure that the contact is clean (no voltage should be present) (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 15)
  • Installation menu a5 wifi status : MENU WI-FI MENU COURT “A5” Vous pouvez vérifier l'état de votre connexion Wi-Fi. (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 22)
  • Installation menu drive status : Ce menu est accessible sans mot de passe et permet d’afficher des informations utiles concernant le fonctionnement. (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 23)
  • Installation menu fan switch off delay : Fan switch off delay (set 150 S) (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 29)
  • Installation menu generated code : Ceci est le code généré par Cattani S.p.A. Chaque appareil possède un code unique. (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 27)
  • Installation menu inverter calibration : Calibration inverter Réservé aux réglages en usine. (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 30)
  • Installation menu inverter status : Ce menu est accessible sans mot de passe et il permet de visualiser certains paramètres concernant l’état de fonctionnement de l'aspirateur. (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 25)
  • Installation menu minimum medium vacuum levels : Minimum vacuum level (only Micro Smart and Micro Smart Cube) (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 28)
  • Installation menu pump switch off delay : Pump switch off delay (max. 3600 t) (Source : TURBO SMART, TURBO SMART TS, TURBO SMART 2V, TURBO SMART CUBE, p. 29)
  • Installation menu surgery vacuum level : Surgery vacuum level (only Micro Smart and Micro Smart Cube) (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 29)
  • Installation menu switch off delay : Switch off delay (max. 300 S) (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 29)

User maintenance

  • Consumable amalgam container : Replace with a new container (043132) (Source : Smart User Maintenance Guide (Cattani ESAM UK), p. 8)
  • Consumable antifoaming tablets : Sanitising Antifoaming Tablets 040825 Stops foam build up, which can cause an interruption in the aspiration. 50 per box. (Source : Smart User Maintenance Guide (Cattani ESAM UK), p. 3)
  • Consumable puli jet classic : Puli Jet Classic (4 x 5 litre bottle) 040715 Cleans, sanitises and deodorises dental suction units. 5 litres makes up to 250 litres of cleaner. (Source : Smart User Maintenance Guide (Cattani ESAM UK), p. 3)
  • Consumable puli jet plus 2 0 range of action : Detergent disinfectant with bactericide, fungicide, virucide (HBV, HCV, HIV) and tuberculocide, proven effective in less than 15 minutes. Conforms to EN14476. Anti-scale. (Source : Smart User Maintenance Guide (Cattani ESAM UK), p. 3)
  • Consumable pulse cleaner code : Pulse Cleaner 040720 Pulse Cleaner is a turbulence-maker. (Source : Smart User Maintenance Guide (Cattani ESAM UK), p. 3)
  • Maintenance 12 months interval condition : EVERY 12 MONTH If required (routine maintenance not sufficient) (Source : Manutenzione straordinaria Turbo-Smart / Micro-Smart, p. 2)
  • Maintenance amalgam 95 percent alarm : When the 95% level alarm is displayed, make arrangements to have the amalgam container replaced at an appropriate time (to do this the system will need to be turned off) (Source : Smart User Maintenance Guide (Cattani ESAM UK), p. 7)
  • Maintenance daily disinfection : Jet plus 2.0 disinfectant with anti-scale agent (A) using the Pulse Cleaner (B) (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 19)
  • Maintenance dental unit filters : It is recommended that you clean the filters on the dental unit and replace the Antifoaming Tablets (if used) (Source : Smart User Maintenance Guide (Cattani ESAM UK), p. 6)
  • Maintenance disinfect exterior : Désinfecter également l'extérieur de la machine. (Source : TURBO-SMART, TURBO-SMART TS, TURBO-SMART 2V, TURBO-SMART CUBE, p. 20)
  • Maintenance every intervention temperatures and alarms : AT ANY INTERVENTION • Check maximum detected temperatures and all alarm signals* Intervene accordingly. (Source : Manutenzione straordinaria Turbo-Smart / Micro-Smart, p. 2)
  • Maintenance occasional aspirator filter : Clean and disinfect the aspirator's filter (6) (Source : Manutenzione ordinaria Turbo-Smart / Micro-Smart, p. 2)

3,649.00 € 3649.0 EUR 3,649.00 €

3,160.82 €

Not Available For Sale

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days